<Value=0> "√"
Shown/Entered value: <Value=0>
Factory default: 5
Example: Enable Double Call feature.
15 02 0 √
8.2.6. KEY Arm/Disarm Settings
Alarm can be armed by using which was connected to the zone. Look at zone
connection type for details page 55
Contact Type
The connected key can be set pulse or continuously contact. The meaning o these
selections in these addresses are below;
2.Option=Pulse Mode(off), Continues Mode(off)
Address 16 01. < IP >
Display for settings:
LED 16 01 (wait)
LCD PANEL SETTINGS→KEY SETTINGS→KEY A/D SETTING (wait)
Change for settings:
LED 16 01 <Value> "√"
LCD PANEL SETTINGS→KEY SETTINGS→KEY A/D SETTING
<Value> "√"
Shown/Entered value: <Value>, Only 2 option
Factory default: Pulse Mode
Example: To set key zone to continuous mode.
16 01 2 (turn on) √
Key Partitions
Partitions that is selected here is armed by key zone. The meaning o these selections
in these addresses are below;
ABCD: 1.option=A, 2.option=B, 3.option=C, 4. option=D
SPT: 1.option=Interior, 2.option=Window, 3.option=Door, 4.option=Exterior
If it is used with SPT, only 1=Interior is recommended setting. Page 30 for
the details.
Address 16 02. < IP >
Display for settings:
LED 16 02 (wait)
LCD PANEL SETTINGS→KEY SETTINGS→KEY A/D SETTING (wait)
PARTITIONS:
Change for settings:
LED 16 02 <Value> "√"
LCD PANEL SETTINGS→KEY SETTINGS→KEY A/D SETTING
PARTITIONS: <Value> "√"
Shown/Entered value: <Value>, 1,2,3,4 multi selection from above list
Factory default: All partitions selected
Example: To select all partition for Key
16 02 1 (turn on) 2 (turn on) 3 (turn on) 4 (turn on) √