VAP416 Installation & Operation Manual
TD-1/07-004
64 / 81
Display for settings:
LED 44 30 (wait)
LCD USER SETTINGS→KEYPADLERİ→30-AUTHORISED (wait)
KEYPADS:
Change for settings:
LED 44 30 <Value> "√"
LCD USER SETTINGS→KEYPADLERİ→30-AUTHORISED
KEYPADS:<Value>
Shown/Entered value: <Value>, 1...4 multi selection from above list
Factory default: All selected
8.5.6. Limitations
Meaning
Option
On
Off
User can not Arm
1
Yes
No
User can not Disarm
2
Yes
No
One time useable code
3
Yes
No
Daily Code
4
Yes
No
User can not make bypass
5
Yes
No
8.5.6.1 User Limitations
User 1 Limitations
Address 45 01. < MP >
Display for settings:
LED 45 01 (wait)
LCD USER SETTINGS→LIMITATIONS→01-LIMITATIONS (wait)
Change for settings:
LED 45 01 <Value> "√"
LCD USER SETTINGS→LIMITATIONS→01-LIMITATIONS
<Value>
Shown/Entered value: <Value>, 1...5 multi selection from the table
Factory default: Nothing selected
Example: To cancel disarm permission of User 1 do.
45 01 2 (turn on) √
User 2...29 Limitations
Address 45 02...45 29. < MP >
Factory default: Nothing selected
8.5.6.2 Guest Limitations
Address 45 30. < MP >
Display for settings:
LED 45 30 (wait)
LCD USER SETTINGS→LIMITATIONS→30-LIMITATIONS (wait)
Change for settings:
LED 45 30 <Value> "√"
LCD USER SETTINGS→LIMITATIONS→30-LIMITATIONS
<Value>
Shown/Entered value: <Value>, 1...5 multi selection from the table.
Factory default: 4 (Daily Code) selected