VAP416 Installation & Operation Manual
TD-1/07-004
60 / 81
ABCD: 1.option=A, 2.option=B, 3.option=C, 4. option=D
SPT: 1.option=Interior, 2.option=Window, 3.option=Door, 4.option=Exterior
If it is used with SPT, only 1=Interior is recommended setting. Page 30 for
the details.
Keypad 1 Partition
Address 31 01. < IP >
Display for settings:
LED 31 01 (wait)
LCD KEYPAD SETTING→PARTITIONS→AUTHORISED (wait)
PARTITIONS:
Change for settings:
LED 31 01 <Value> "√"
LCD KEYPAD SETTING→PARTITIONS→AUTHORISED
PARTITIONS: <value>
Shown/Entered value: <Value>, 1,2,3,4 multi selection from above list
Factory default: 1,2,3,4 selected
Example: To assign keypad 1 to A and B partitions do.
31 01 1 (turn on) 2 (turn on) 3 (turn off) 4 (turn off)
Keypad Partitions from 2 to 4
Addresses 31 02 ... 31 04. < IP >
Factory default: 1,2,3,4 selected
8.5. USER SETTINGS
The codes and permission of all users can be limited according to hour, day, part,
keypad. The limited is a weekly planning. The code of master, engineer, duress, pc
access can not be limited. Only master can access to all limitations.
8.5.1. Start Time
After adjusted hour, the code of user and guest is activated.
8.5.1.1 User Start Time
User 1 Start Time
Address 40 01. < MP >
Display for settings:
LED 40 01 (wait)
LCD USER SETTINGS→START TIME→01-START (wait)
HOUR:
Change for settings:
LED 40 01 <HHMM> "√"
LCD USER SETTINGS→START TIME→01-START
HOUR:<HHMM>
Shown/Entered value: HH=hour, MM=minute, number
Factory default: 00:00
Example: To set Start time of User 1 to 08:10 do.
40 01 0 8 1 0
User 2...29 Start Time
Address 40 02...40 29. < MP >
Factory default: 00:00