VAP416 Installation & Operation Manual
TD-1/07-004
30 / 81
4.3.8 Error Codes
If there is a long "beep" sound, it means there is an error in the operation. Under this
condition, some zone leds which shows error type are lightning with "trouble" LED.
Meaning
Description
Invalid address
Invalid address has been entered
Invalid data
Entered data is invalid
No permission
Your permissions are limited
Panel can not be armed
There is an opened zone
Panel is already armed
The partitions you try to arm are already armed
Invalid Code
Invalid code has been entered
Out of limit
Entered value is out of limit. For example; if you
enter a value over than 23 for the time
Type of data is wrong
Length of data that you have entered is wrong.
For example; if you enter 2 digits instead of 4
digits
Feature is closed
Feature you have tried to use is closed
Invalid function
The function you are trying to use is invalid
Invalid parameter
The parameter you are trying to use is invalid.
Example: If you try to test CMS 3, keypad
displays this trouble
Out of time limit
If user is trying to use keypad out of his/her time
limit, keypad displays this trouble
Not allowed in this keypad
User is not allowed in this keypad
Invalid setting
Setting you have made doesn't like as expected
Unknown trouble
Trouble is not known
Communication error
Keypad can't communicate with panel
5. SMART PARTITION TECHNOLOGY (SPT)
There are 2 partitions which you select one for other. First one is true partitioning. At
this partitioning, zones are parted by technician to A.B.C.D. parts. Second one is SPT
at this mode, zones are parted by the panel automatically. These parts are door,
window, outside, inside. There are the pictures of the parts on the buttons. So, at the
fast arming, user easily can arm any part. The other zones are the same a for SPT
For example, at SPT, the zone which is 24 hours zone is sent the alarm signal
without arming, if the zone sends alarm signal.
Door types zones are related to C button and LED, window
types zones are related to B and LED, indoor types zones
are related to A button and LED, outdoor types zones are
related to D button and LED. If there is a moving, related
zone LED lights. Windows can be fast armed by using B,
doors can be fast armed by using C. The fast arming can
be done by using A, when you are in the house. When you
are out of the house, the fast arming can be done by using
D button.
5.1 RUNNING OF THE PANEL AT THE SPT MODE
All adjustments which are for true partitioning, are disable in SPT mode. But all
adjustments are kept in the memory.