VAP416 Installation & Operation Manual
TD-1/07-004
37 / 81
and the types of pressing is indicated. The indication with LCD explains the menu
array, pressing keys and the pressing type.
8.1. MAIN CONFIGURATIONS
8.1.1. Time/Date Settings
Time Settings
Address 01 01.< IP, MP >
Display for settings:
LED 01 01 (wait)
LCD BASIC SETTINGS→CLOCK SETTING→CLOCK SETTING (wait)
HOUR:
Change for settings:
LED 01 01 <HHMM> "√"
LCD BASIC SETTINGS→CLOCK SETTING→CLOCK SETTING
HOUR: <HHMM> "√"
Shown/Entered value: HH=hour, MM=minute, number
Factory default: 00:00
Example: Setting clock to 09:17 ; 01 01 0 9 1 7
Date Settings
Address 01 02.< IP, MP >
Display for settings:
LED 01 02 (wait)
LCD BASIC SETTINGS→CLOCK SETTING→CLOCK SETTING (wait)
DATE:
Change for settings:
LED 01 02 <GGAAYY> "√"
LCD BASIC SETTINGS→CLOCK SETTING→CLOCK SETTING
DATE: <DDMMYY> "√"
Shown/Entered value: DD = day, MM = month, YY = year, number
Factory default: 00/00/00
Example: Setting date to 15/10/2004 ; 01 02 1 5 1 0 0 4
Day of week
Address: 01 03 < IP, MP >
To see value :
LED 01 03 (wait)
Day of week : 1=Monday, 2=Tuesday,......, 7=Sunday (single choice)
Default value : 1= Monday
Note: This address is only readable. Panel sets date automatically. LCD Keypad
displays date on screen.
Example: Display day 01 03 √
8.1.2. Entry Delays
If any zone at a partition selected as Entry/Exit zone on "Zone Settings", entry delay
is defined hereby with this setting. Follower zone must be in same partition with
Entry/Exit zone. (Look at Zone Settings page 57)
Entry Delay of A Partition
Entry delay is only configured here when SPT is used.