Address 60 02. < IP >
Display for settings:
LED 60 02 (wait)
LCD MODULES→WIRELESS MODULE→SUPERVISORY INT. (wait)
Change for settings:
LED 60 02 <Value> "√"
LCD MODULES→WIRELESS MODULE→SUPERVISORY INT.
<Value> HOUR
Shown/Entered value: <Value>, Value between 1...255 as hour
Factory default: 6
Example: To set supervisory interval 24 do.
60 02 2 4
8.8.3. Zone Expansion Module
The module is connect to panel for expanding the zone number.
1.option=Enabled/Disabled
Address 61 01. < IP >
Display for settings:
LED 61 01 (wait)
LCD MODULES→EXP ZONE SETTING→EXP ZONE SETTING (wait)
Change for settings:
LED 61 01 <Value> "√"
LCD MODULES→EXP ZONE SETTINGEXP ZONE SETTING
<Value>
Shown/Entered value: <Value>, 1 options enable/disable only
Factory default: Disable
Example: To enable Zone Module do.
61 01 1 (Turn on) √
8.9 PROGRAMMING ADDRESSES
ADR.
FUNCTION
VALUE
DEFAULT
VALUE
DETAILS
INST.
VALUE
01 01
Time
HH MM HH=hour, MM=minute
00:00
IP,MP
Page:37
01 02
Date
DD MM YY
DD=day, MM=month, YY=year (last 2 digit)
00/00/00
IP,MP
Page:Hata!
Yer işareti
tanımlanmamı
ş.
01 03
Day of week
1=Monday...,7=Sunday
Read only
IP,MP
Page:Hata!
Yer işareti
tanımlanmamı
ş.
Read only
02 01
02 02
02 03
02 04
Entry Delays
A Partition
B Partition
C Partition
D Partition
0...255 seconds
15
0
0
0
IP
Page:37
For SPT:30
03 01
03 02
03 03
03 04
Exit Delays
A Partition
B Partition
C Partition
D Partition
0...255 seconds
15
0
0
0
IP
Page:38
For SPT:30
04 01
04 02
Account No
CMS 1
CMS 2
Account number (4 digit)
0000
0000
IP
Page:39