Loading...
VAP416 Installation & Operation Manual
TD-1/07-004
52 / 81
Display for settings:
LED 14 01 (wait)
LCD PANEL SETTINGS→TIMERS→TMR 1 SETTINGS (wait)
Change for settings:
LED 14 01 <Value> "√"
LCD PANEL SETTINGS→TIMERS→TMR 1 SETTINGS
<Value> "√"
Shown/Entered value: <Value>, 1...8 multi selection from the table.
Factory default: Nothing selected
Example: To activate PGM1 in specific time do
14 01 1 (turn on) 2 (turn on) √
1
st
Timer Days
This setting provides selects on which day timer controls PGM. Meaning of options is
in the following;
1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday,
7=Sunday
Address 14 02. < IP, MP >
Display for settings:
LED 14 02 (wait)
LCD PANEL SETTINGS→TIMERS→TMR 1 SETTINGS (wait)
DAYS:
Change for settings:
LED 14 02 <Value> "√"
LCD PANEL SETTINGS→TIMERS→TMR 1 SETTINGS
DAYS: <Value> "√"
Shown/Entered value: <Value>, 1...7 multi selection from above list
Factory default: All selected
Example: To select days except Saturday and Sunday do
14 02 1 (turn on) 2 (turn on) 3 (turn on) 4 (turn on) 5 (turn on) √
Time of Timer 1
Timer is running at defined time.
Address 14 03. < IP, MP >
Display for settings:
LED 14 03 (wait)
LCD PANEL SETTINGS→TIMERS→TMR 1 SETTINGS (wait)
HOUR:
Change for settings:
LED 14 03 <HH MM> "√"
LCD PANEL SETTINGS→TIMERS→TMR 1 SETTINGS
HOUR: <HH MM> "√"
Shown/Entered value: HH=hour, MM=minute, number
Factory default: 00:00
Example: To set time as 17:30
14 03 1 7 3 0
Note: Other timers are programmed samely.
8.2.5. Remote Controlling
User can call controls some features of Panel or PC.
Enable/Disable Remote Control

Table of Contents