VAP416 Installation & Operation Manual
TD-1/07-004
67 / 81
Change for settings:
LED 50 05 <HHMM> "√"
LCD COMMUNICATOR→GENERAL SETTINGS→FIRST TEST AT
HOUR: <HHMM>
Shown/Entered value: HH=hour, MM=minute, number
Factory default: 00:00
Example: To set Periodic Test First Time to 19:50 do.
50 05 1 9 5 0
8.6.6. Interval Between Calls
The timing which is between first calling and second calling is adjusted.
Address 50 06. < IP >
Display for settings:
LED 50 06 (wait)
LCD COMMUNICATOR→GENERAL SETTINGS→REDIALING PAUSE (wait)
Change for settings:
LED 50 06 <Value> "√"
LCD COMMUNICATOR→GENERAL SETTINGS→REDIALING PAUSE
<Value> SANİYE
Shown/Entered value: <Value>, Value between 1...30 as second
Factory default: 3 second
Example: To set interval between class to 5 second do.
50 06 5
8.6.7. Central Monitoring Station Communication Format
Central monitoring station communication format is configured here.
0=ContactID, 2=SIA
CMS 1 Communication Format
Address 50 07. < IP >
Display for settings:
LED 50 07 (wait)
LCD COMMUNICATOR→GENERAL SETTINGS→CMS 1 FORMAT (wait)
Change for settings:
LED 50 07 <Format> "√"
LCD COMMUNICATOR→GENERAL SETTINGS→CMS 1 FORMAT Select using
<Format> B(left) and C(right) buttons)
Shown/Entered value: <Format>, CMS format number
Factory default: 0 (ContactID)
Example: To set CMS 1 contact as SIA do.
50 07 2
CMS 2 Communication Format
Address 50 08. < IP >
Display for settings:
LED 50 08 (wait)
LCD COMMUNICATOR→GENERAL SETTINGS→CMS 2 FORMAT (wait)
Change for settings:
LED 50 08 <Format> "√"
LCD COMMUNICATOR→GENERAL SETTINGS→CMS 2 FORMAT Select using
<Format> B(left) and C(right) buttons)
Shown/Entered value: <Format>, CMS format number