3.1.2.6. AT&W - Store Current Configuration
Execution command stores on profile <n> the complete configuration of the device.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
No
No
-
2
AT&W[<n>]
Parameter:
Name
Type
Default
Description
<n>
integer
0
profile identifier
Value:
0,1
:
profile identifiers
If parameter is omitted, the command has the same behavior of AT&W0.