ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 418 of 545 2020-04-15
3.13.35. AT#SCFGEXT3 - Socket Configuration Extended 3
This command sets the socket configuration extended parameters for features not included in #SCFGEXT
command nor in #SCFGEXT2 command.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Required
Auto
No
-
2
AT#SCFGEXT3=<connId>,<immRsp>[,<closureTypeCmdModeEnabling>[,<fastSRING>[,<ssend
Timeout>[,<unusedD>]]]]
Parameters:
Name
Type
Default
Description
<connId>
integer
N/A
socket connection identifier
Value:
1÷max
:
socket connection identifier value (max
value is returned by the test command)
<immRsp>
integer
0
enables #SD command mode
immediate response
Values:
0
:
#SD in command mode (see #SD) returns after
the socket is connected
1
:
#SD in command mode returns immediately;
then the state of the connection can be read by
the AT command #SS
<closureTypeCmdModeEnabling>
integer
0
it has no effect and is
included only for backward
compatibility
Value:
0
:
factory default
<fastSRING>
integer
0
it has no effect and is
included only for backward
compatibility
Value:
0
:
factory default
<ssendTimeout>
integer
0
timeout for #SSEND
Values:
0
:
no timeout
100÷600
:
timeout in 100 msec units
<unusedD>
mixed
0
unused parameter
Value:
0
:
factory default