ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 89 of 545 2020-04-15
3.1.3.8. ATS12 - Escaper Prompt Delay
The command manages the prompt delay between two different escape characters.
SIM Presence
Setting saved
Can be aborted
MAX timeout
SELINT
Not required
Specific profile
No
-
2
ATS12=<time>
Set command sets:
the minimum period, before receipt of the first character of the three escape character
sequence, during which no other character has to be detected in order to accept it as valid
first character;
the maximum period allowed between receipt of first or second character of the three
escape character sequence and receipt of the next;
the minimum period, after receipt of the last character of the three escape character
sequence, during which no other character has to be detected in order to accept the
escape sequence as a valid one.
Parameter:
Name
Type
Default
Description
<time>
integer
50
delay expressed in fiftieth of a second
Value:
2÷255
:
expressed in fiftieth of a second
The minimum period S12 has to pass after CONNECT result code too, before a received
character is accepted as valid first character of the three escape character sequence.
ATS12?
Read command returns the current value of S12 parameter.
The format of the numbers in output is always 3 digits, left-filled with 0s