ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 367 of 545 2020-04-15
0
:
data represented as text
1
:
0ata represented as sequence of hexadecimal numbers (from 00
to FF). Each octet of the data is given as two IRA character long.
Additional info:
These are the SRING formats, depending on <srMode> setting:
if <srMode> = 0 (Normal):
SRING: <connId>
if <srMode> = 1 (Data amount):
SRING: <connId>,<recData>
if <srMode> = 2 (Data view):
SRING: <connId>,<recData>,<data>
if <srMode> = 3 (Data view with UDP datagram information):
SRING: <sourceIP>,<sourcePort>,<connId>,<recData>,<dataLeft>,<data>
Name
Type
Default
Description
<recData>
integer
-
amount of data received on the socket connection
number <connId>
<data>
mixed
-
data received displayed following
<recvDataMode> value
<sourceIP>
string
-
IP address of the source of data
<sourcePort>
string
-
IP port of the source of data
<dataLeft>
integer
-
number of bytes left in the UDP datagram
Keepalive is available only on TCP connections.
For the behavior of #SL and #SLUDP in case of auto response mode or in case of no
auto response mode, see the description of the two commands.
AT#SCFGEXT?
Read command returns the current socket extended configuration parameters values for all the six
sockets, in the format:
#SCFGEXT: <connId
1
>, <srMode>,<dataMode>,<keepalive>,<ListenAutoRsp>,0<CR><LF>
. . .
#SCFGEXT:<connId
conMax
>,<srMode>,<dataMode>,<keepalive>, <ListenAutoRsp>,0<CR><LF>
AT#SCFGEXT=?
Test command returns the range of supported values for all the sub parameters.