EasyManua.ls Logo

Telit Wireless Solutions ME910G1 - Page 371

Telit Wireless Solutions ME910G1
545 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ME310G1/ME910G1/ML865G1 AT Commands Reference Guide
80617ST10991A Rev.4 Page 371 of 545 2020-04-15
Set the new transmission timer behavior for <connId>=1 and <connId>=2 sockets.
AT#SCFGEXT2=1,1
OK
AT#SCFGEXT2=2,1
OK
Check the current extended configuration of the six sockets
AT#SCFGEXT2?
#SCFGEXT2: 1,1,0,0,0,0
#SCFGEXT2: 2,1,0,0,0,0
#SCFGEXT2: 3,0,0,0,0,0
#SCFGEXT2: 4,0,0,0,0,0
#SCFGEXT2: 5,0,0,0,0,0
#SCFGEXT2: 6,0,0,0,0,0
OK
Check the current configuration of the six sockets
AT#SCFG?
#SCFG: 1,1,300,90,600,50
#SCFG: 2,1,300,90,600,50
#SCFG: 3,1,300,90,600,50
#SCFG: 4,2,300,90,600,50
#SCFG: 5,2,300,90,600,50
#SCFG: 6,2,300,90,600,50
OK
Change the <txTo> data sending timeout of the <connId>=1 socket.
AT#SCFG=1,1,300,90,600,30
OK