5-62 4203780 First Edition
HYDROSTATIC POWER TRAIN
5
Figure 5-62
NOTES
Label all hydraulic hoses before disconnecting to
ensure correct installation.
Plug hydraulic hoses after disconnecting to prevent
the loss of hydraulic oil.
12. Disconnect hydraulic line (22) from gear pump.
13. Remove nut (24), lock washer (25), screw (27), and
flat washer (28) from traction linkage (23) and
traction bell crank (26).
14. Disconnect hydraulic hose (29).
Figure 5-63
15. Disconnect hydraulic line (35).
16. Disconnect hydraulic hose (34) at tee fitting.
17. Remove four screws (31), lock washers (32), and flat
washers (33), and remove the platform support (30).
Figure 5-64
Figure 5-65
NOTE
Perform steps 18 through 21 for both lift cylinders.
18. Support both front lift arms.
19. Remove screw (38), lock washer (39), and retaining
pin (40).
20. Remove pin (37) from the front lift cylinder (36) and
front lift arm support (41).
21. Remove cotter pin (42) and lift cylinder pin (44), and
lower the lift cylinder (43) to the floor.
TN2047
22
23
28
29
26
24
25
27
TN2048
30
31
32
32
34
35
31
33
33
TN2051
38
39
37
40
36
41
TN2052
44
43
42