4. SYSTEM MODE (For Service Persons and System Administrators) EO13-33005
4.8 RAM Clear
4- 69
4.8 RAM Clear
In the RAM Clear mode, clearing the Maintenance Counter and initializing the Parameters are possible.
After replacing the print head, ribbon motor, or platen, perform a maintenance clear.
4.8.1 RAM Clear Operation Example
4.8.2 NO RAM Clear (NO RAM CLEAR)
This mode prevents RAM clear from being performed mistakenly.
No RAM clear mode
A mode to prevent RAM clear from being performed mistakenly
[POWER]
NO RAM CLEAR
<7>SENSOR ADJUST
[PAUSE]
System mode menu display (RAM Clear)
PARAMETER CLEAR
Parameter clear mode
[PAUSE]
MAINTE.CNT CLEAR
Maintenance counter clear mode
<7>SENSOR ADJUST
System mode menu display (RAM Clear)
[FEED] and [PAUSE]
[POWER]
<0>SHUTDOWN
Hold down the [POWER] key for 3 seconds or more.
[POWER]
Power OFF
While holding down the [FEED] key, press the [PAUSE] key.
System mode menu display (Shutdown)
<7>RAM CLEAR
<7>RAM CLEAR
NO RAM CLEAR
Automatic sensitivity adjustment (Factory default)
System mode menu display (RAM clear)
Completion of setting
No RAM Clear
[POWER]
[POWER]
The power is turned off.

Table of Contents

Other manuals for Toshiba B-EP2DL Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba B-EP2DL Series and is the answer not in the manual?

Toshiba B-EP2DL Series Specifications

General IconGeneral
BrandToshiba
ModelB-EP2DL Series
CategoryPrinter
LanguageEnglish

Related product manuals