4. SYSTEM MODE (For Service Persons and System Administrators) EO13-33005
4.5 Printer Parameter Fine Adjustment
4- 46
4.5.5 Reflective Sensor Manual Threshold Fine Adjustment (THRESHOLD<R>)
This parameter is to set a threshold voltage of the black mark sensor.
Notes:
1. When the [FEED] key is pressed, the menu moves in the opposite direction from when the [PAUSE]
key is pressed.
2. When the [PAUSE] key is pressed while the [FEED] key is held down, or when the [POWER] key is
pressed for 3 seconds or more, the display returns to the system mode menu (ADJUST SET).
3. When the [PAUSE] key or [FEED] key is pressed for 0.5 seconds or more during this fine adjustment
setting, repeat mode is enabled and the key pressed is repeatedly entered.
4. The change in the fine adjustment value becomes effective when the [POWER] key is pressed after
setting, then stored in the backup memory.
5. The factory default value is 1.0V.
6. This setting is effective only in the TPCL and TPCL1 modes.
[PAUSE]
THRESHOLD<R>0.0V
THRESHOLD<R>0.1V
THRESHOLD<R>0.2V
THRESHOLD<R>3.9V
THRESHOLD<R>4.0V
[FEED]

Table of Contents

Other manuals for Toshiba B-EP2DL Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba B-EP2DL Series and is the answer not in the manual?

Toshiba B-EP2DL Series Specifications

General IconGeneral
BrandToshiba
ModelB-EP2DL Series
CategoryPrinter
LanguageEnglish

Related product manuals