4. SYSTEM MODE (For Service Persons and System Administrators) EO13-33005
4.4 Parametr Setting
4- 32
(2) Manual Selection (ESC.LF.NUL)
The control code of the command is [ESC](1BH),[LF](0AH),[NUL](00H), and the control code selection
is not performed.
(3) Manual Selection ({.|.})
The control code of the command is {(7BH),|(7CH),}(7DH), and the control code selection is not
performed. Data of 00H to 1FH is ignored and discarded of in this mode. However, data of 00H to 1FH
becomes valid while processing the Graphic command or Writable Character command in hexadecimal
mode. {.|.} cannot be used in the data of the Data command or Display command.
Power ON
Reads received data.
<
Is the received data ESC?
>
Assume a control code to be
ESC.LF.NUL.
Command processing
<Is the received data { ?>
Assume a control code
to be {.|.}.
Discards of read data.
Yes
No
Yes
No

Table of Contents