Encompass 4 Reader System Guide
7-14
Command #453 enables the translation of tags in AAR and ATA formats. Specific
data fields, such as owner ID and car number, will be extracted from these tags,
translated according to AAR or ATA standards, and converted to ASCII. Tags that are
not programmed in AAR or ATA format will be directly converted to ASCII. The
reader will not attempt to translate data from half-frame or dual-frame tags.
Reader message:
Done
454 Disable Multi-tag Sort (Factory Default)
Command #454 is a default set in the factory to disable the multi-tag sort function.
Reader response:
Done
455 Enable Multi-tag Sort
Command #455 enables the multi-tag sort function that allows the reader to identify
unique tags within a group of Intellitag-based tags. Multi-tag sort allows full operation
of the tags and reader to be carried out with a limited number of tags in the presence of
the reader.
Reader response:
Done
Note: Enabling the multi-tag sort function adversely affects the vehicle speed at
which tags may be read. If there is only one Intellitag-based tag in the vehicles of the
target population, multi-tag sort should be disabled.
456 Enable eGo Plus Tag Initialization During Multi-tag Sort
(Factory Default)
Command #456 enables the reader to send the eGo Plus Tag initialize command as
part of the multi-tag sort function. When the reader sends the eGo Plus Tag initialize
command, all tags in the RF field reenter the sort process.
Reader response:
Done
457 Disable eGo Plus Tag Initialization During Multi-tag Sort
Command #457 disables the reader from sending the eGo Plus Tag initialize com-
mand as part of the multi-tag sort function. Any eGo Plus Tags already identified by
the reader during the sort process will not be re-identified as long as they remain pow
-
ered in the RF field. The reader will only identify new tags that come into the RF field
or tags that do not remain powered in the RF field.
Reader response:
Done