Encompass 4 Reader System Guide
7-16
46NN Set Wiegand Retransmit Interval
Command #46NN sets the time delay to control the reader retransmission of Wiegand
data of a tag remaining in the read zone where NN is a hexadecimal code from
01 to
FF.
Note: The actual value of the Wiegand retransmit interval may vary depending on the
operative tag read mode and the type of tag in the read field.
For example, 10 = 16 seconds and FF = 255 seconds. The factory default is 4601 (1
second).
Uppercase or lowercase characters are allowed for NN; for example, hex digits A
through F or a through f.
Reader response:
Done
480 Disable ATA
Command #480 disables the reader from reading ATA protocol tags.
481 Enable ATA
Command #481 enables the reader to read ATA protocol data from tags if the reader
is programmed to read this tag protocol.
482 Disable eGo
Command #482 disables the reader from reading protocol eGo data from tags.
483 Enable eGo
Command #483 enables the reader to read factory-programmed eGo data from tags if
the reader is programmed to read this tag protocol.
484 Disable SeGo
Command #484 disables the reader from reading SeGo protocol data from tags.
485 Enable SeGo
Command #485 enables the reader to read SeGo protocol data from tags if the reader
is programmed to read this tag protocol.
486 Disable IAG
Command #486 disables the reader from reading IAG protocol data from tags.
487 Enable IAG
Command #487 enables the reader to read IAG protocol data from tags if the reader
is programmed to read this tag protocol.
488 Disable eATA