Commands
7-43
Command #6
7N sets the output pulse duration for the command #621 Predefined
Output Control. This command specifies the length of time that output line(s) will be
asserted upon receipt of a valid and unique tag ID. The factory default setting is 228
ms. The variable N specifies an output pulse duration of 48 ms to 752 ms.
Uppercase or lowercase characters are allowed
for N; for example, hex digits A
through F or a through f. The command numbers and corresponding output pulse
durations are shown in Table 7-18.
Table 7-18 Output Pulse Duration Commands
Command Duration
670 4
671 8
672 12
673 16
674 20
675 24
676 32
677 40
678 48
679 60
67A 76
67B 152
67C 228 (factory default)
67D 300
67E 376
67F 752
Additional IDs may be acquired during the selected output pulse duration; however,
the timing restarts upon each successive ID acquisition. This command should be used
with discretion. For example, when the tag acquisition interval is short compared to
the selected pulse duration, distinct pulses may not be generated.
Reader response:
Done or Error