8-5
a. Local laws apply. The authorized frequency band for the TransCore Encompass 4
Reader in the United States is 911.75 MHz to 919.75 MHz. Contact TransCore if your
application requires a frequency outside of this range.
Configuring Parameters with Terminal Emulation Software
To configure the Encompass 4 Reader using a PC and terminal emulation software to
manually enter Encompass 4 Reader host commands, follow the instructions in the
Alternate group select Disabled 496
Reader ID number 00 6000
Communications protocol Basic 610
Error correcting protocol (ECP)
timeout
12.7 sec 612FE
Flow control Software (XON/XOFF) 6141
Echo mode Enabled 6171
Sense output control Predefined 621
RF-by-input control Enabled 641
ATA operating range Maximum 6431F
RF attenuation Full power 64400
eGo and eGo Plus Tag operating
range
Maximum 6451F
Sense output pulse duration 228 ms 67C
Presence without tag reports Disabled 6900
RF-off control Timeout or no presence 6922
RF timeout Never true 693F
Input inversion Disabled 6940
Serial number NNNNNN 695
Store hardware configuration Hardware configuration not
known
696
Input status change reports Disabled 820
Automatic periodic RF status
report
Disabled 830
Table 8-2 Encompass 4 Reader Default Configuration Settings (continued)