EasyManua.ls Logo

TransCore encompass 4 - Enable Fifth Alternate Group Select

TransCore encompass 4
306 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Encompass 4 Reader System Guide
7-18
Command #494 is a default set in the factory to disable the fifth a
lternate group select
function.
Reader response:
Done
495 Enable Fifth Alternate Group Select
Command #495 enables the fifth alternate group select function that allows the reader
to distinguish tags meeting specific criteria pre-programmed into the tags.
Caution
When fifth alternate group select is enabled, tags n
ot programmed to meet the spec-
ified criteria will not be read.
Reader response:
Done
496 Disable Alternate Group Select (Factory Default)
Command #496 disables the alternate group select function that allows the reader to
distinguish tags meeting specific criteria pre-programmed into the tags.
Reader response:
Done
497 Enable Alternate Group Select
Command #497 enables the alternate group select function that allows the reader to
distinguish tags meeting specific criteria pre-programmed into the tags.
Reader response:
Done
Reader Status — Command Group 5
Group 5 commands provide status reports on the parameters and operation of the
reader.
505 Display Software Version
Command #505 displays the reader model number, software version information, and
assigned serial number.
Reader message:
Model E4 Series Ver X.XX SNSSSSSS
where
X.XX Version number

Table of Contents

Other manuals for TransCore encompass 4