Commands
7-17
Command #4
88 disables the reader from reading factory-programmed eATA data
from tags.
489 Enable eATA
Command #489 enables the reader to read factory-programmed eATA data from eGo
Plus or eGo tags. This option must be enabled to obtain Wiegand data from eGo Plus
or eGo tags.
490 Disable Third Alternate Group Select (Factory Default)
Command #490 is a default set in the factory to disable the third alternate group
select function.
Reader response:
Done
491 Enable Third Alternate Group Select
Command #491 enables the third alternate group select function that allows the
reader to distinguish tags meeting specific criteria pre-programmed into the tags.
Caution
When third alternate group select is enabled, tags not programmed to me
et the spec-
ified criteria will not be read.
Reader response:
Done
492 Disable Fourth Alternate Group Select (Factory Default)
Command #492 is a default set in the factory to disable the fourth alternate group
select function.
Reader response:
Done
493 Enable Fourth Alternate Group Select
Command #493 enables the fourth alternate group select function that allows the
reader to distinguish tags meeting specific criteria pre-programmed into the tags.
Caution
When fourth alternate group select is enabled, tags not programmed
to meet the
specified criteria will not be read.
Reader response:
Done
494 Disable Fifth Alternate Group Select (Factory Default)