The 32-bit Counter Count Direction Control
Controlling Flag of Software High Speed Counter Count Direction
Monitoring Flag of Software High Speed Counter Count Direction
Working Area of the EC1 Expansion Card
Working Area of the EC2 Expansion Card
Working Area of the EC3 Expansion Card
DUTY Instruction Output
When M92 □□ =“OFF”, the C2 □□ is operated as a up counter.
When M92 □□ =“ON”, the C2 □□ is operated as a down counter.
When M92 □□ =“OFF”, the C2 □□ is operated as a up counter.
When M92 □□ =“ON”, the C2 □□ is operated as a down counter.
When C2 □□ is operated a up count, M92 □□ =“OFF”.
When C2 □□ is operated a down count, M92 □□ =“ON”.
EC1 Expansion Card's working area. M9260~M9267= EC1X0~EC1X7;
M9270~M9277=EC1Y0~EC1Y7.
EC2 Expansion Card's working area. M9280~M9287= EC2X0~EC2X7;
M9290~M9297=EC2Y0~EC2Y7.
EC3 Expansion Card's working area. M9300~M9307= EC3X0~EC3X7;
M9310~M9317=EC3Y0~EC3Y7.
Destination #1 for the timing sequence pulse generative instruction DUTY (FNC186).
Destination #2 for the timing sequence pulse generative instruction DUTY (FNC186).
Destination #3 for the timing sequence pulse generative instruction DUTY (FNC186).
Destination #4 for the timing sequence pulse generative instruction DUTY (FNC186).
Destination #5 for the timing sequence pulse generative instruction DUTY (FNC186).
M9350
Y0 axis's external interrupt trigger type. When M9350= “OFF”, the interrupt is triggered by a rising
edge; when M9350= “ON”, that is triggered by a falling edge.
M9370
Y1 axis's external interrupt trigger type. When M9370= “OFF”, the interrupt is triggered by a rising
edge; when M9370= “ON”, that is triggered by a falling edge.
VS1
VS1
VS2
VS2
VSM
VSM
VS3
VS3
Y0 Axis's Positioning Control Flag
Y1 Axis's Positioning Control Flag
M9345
M9346
M9365
M9366
M9340
M9360
M9341
M9361
M9342
M9343
M9344
M9362
M9363
M9364
M9367
M9368
M9369
M9347
M9348
M9349
Y0 axis's status. “OFF” means the Y0 is in the READY status, it is available for a positioning
instruction; while “ON” = BUSY, the Y0 has been occupying.
Y0 axis's pulse output monitor. “ON” means pulse is generating.
Y0 axis's positioning completed ag.
Y0 axis's positioning abnormal stop ag.
Y0 axis's zero home positioning has been completed.
Y0 axis's stop ag (with gradually slow down).
Y0 axis's immediately stop ag.
Y0 axis's table positioning start signal.
Y0 axis's M-code active ag.
Y0 axis's M-code clear command.
Y1 axis's status. “OFF” means the Y1 is in the READY status, it is available for a positioning
instruction; while “ON” = BUSY, the Y1 has been occupying.
Y1 axis's pulse output monitor. “ON” means pulse is generating.
Y1 axis's positioning completed ag.
Y1 axis's positioning abnormal stop ag.
Y1 axis's zero home positioning has been completed.
Y1 axis's stop ag (with gradually slow down).
Y1 axis's immediately stop ag.
Y1 axis's table positioning start signal.
Y1 axis's M-code active ag.
Y1 axis's M-code clear command.
Description
Relay ID
No.
Series

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vigor VS Series and is the answer not in the manual?

Vigor VS Series Specifications

General IconGeneral
BrandVigor
ModelVS Series
CategoryController
LanguageEnglish