Operation
02301/A1
Winterthur Gas & Diesel Ltd.
1/ 2
Engine Start
1. General
Before you start the engine (also, before trials and using starting air to turn the
engine) see:
D 01101 Prepare the Engine for Engine Start
D 01201 Prepare the Fuel Oil System for Operation
D 01301 Prepare the Servo Oil System
D 01401 Prepare the Cylinder Lubricating System.
You can start the engine from the locations that follow:
D The bridge or control room with remote control.
D At the LDU20 in the control room.
D At local control panel on the engine.
2. Engine Start Control Stand in Control Room
Prepare the engine as follows:
1) At the local control panel, push the button CTRL. TR on the LDU20 for transfer
to ECR remote (see 40022, paragraph 3.4 Control Locations).
2) At the control room console, make sure that the remote control has control.
For more procedures to start using the remote control, see the documentation of the
remote control manufacturer.
If you move the telegraph from STOP to a different position, a start signal is released
automatically.
3. Engine Start at the Local Control Panel
You use this mode if e.g. the electronic speed control system or the remote control
becomes defective.
CAUTION
Damage Hazard. The operator must not leave the local
maneuvering stand. The operator must regularly monitor the
speed indication to immediately adjust the fuel supply if the
speed changes.
3.1 Preparation
1) At the local control panel, push the button CTRL. TR. on the LDU20 for transfer
to Local.
Operation during Usual Conditions