Troubleshooting
Phaser 3330 and WorkCentre 3335/3345 Xerox Internal Use Only
Service Manual
2-68
Over Heat Error
The Fuser exceeded the temperature set point.
Applicable Error
10-300: Over Heat error
Initial Actions
Check the Fuser and Fan vents for debris.
Turn the Machine off and then on again.
If the problem persists continue troubleshooting.
Troubleshooting Reference Table
WARNING: Do not touch the fuser while it is hot.
Troubleshooting Procedure Table
Applicable Parts Wiring and Plug/Jack Map Reference
Thermistor, (PL 3.3.2, Parts List 3.3 Fuser)
Fuser, (PL 3.3.36, Parts List 3.3 Fuser)
Phaser 3330 Main PWB Connector Designators
Phaser 3330 Control Panel PWB
Wiring Diagrams for P3330/WC3335/WC3345
WorkCentre 3335/3345 Main PWB Connector Designators
•DADF PWB
•SMPS PWB
Step Actions and Questions Yes No
1. Remove then reinstall Fuser.
Does the error persist?
Go to step 2. Complete.
2. If the problem persists, turn the machine
off and remove the Fuser (PL 3.3.36,
Parts List 3.3 Fuser).
Check if the Fuser connector is
connected properly (CN 3).
Check if the input voltage is normal.
Check if the Thermistor is twisted or
contaminated. Clean or replace the
Thermistor (PL 3.3.2, Parts List 3.3 Fuser).
Does the error persist?
Install a new Fuser (PL
3.3.36, Parts List 3.3
Fuser).
If the problem persists
Install a new Main PWB:
Phaser 3330 (PL
1.0.7, Parts List 1.0
Phaser 3330 Main)
WorkCentre 3335 and
3345 (PL 6.1.7, Parts
List 6.1 WorkCentre
3335/3345 Main).
Complete.