B.3 Parameter Table
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 399
Parameter List
B
C6: Carrier Frequency
C5-20
(275H)
Speed Control Loop Integral Time
during Position Lock
Sets the Speed Control Loop Integral time used during Position Lock.
Default:0.100 s
Min: 0.000 s
Max: 10.000 s
181
C5-50
(B14H)
<45>
Set Vibrational Frequency Filter
Sets the mechanical vibration filter frequency in units of 1 Hz.
Note: Set C5-50 to 0 (Hz) to disable the filter. The frequencies from 1 to 19 Hz cannot be set.
Test equipment may be required to determine the mechanical resonance frequency. Setting
C5-50 to an improper frequency will result in ineffective filtering of the effects of mechanical
resonance.
Default: 0 Hz
Min: 20 Hz
Max: 1000 Hz
181
<4> Default setting value varies by the drive model (o2-04).
<5> Default setting is determined by the control mode (A1-02).
<45> Available in drive software versions PRG: 7200 or later.
No.(Addr.) Name Description Setting Page
C6-03
(225H)
<4> Default setting value varies by the drive model (o2-04).
<39> Available in drive software versions PRG: 7016 or later.
Carrier Frequency
Sets the carrier frequency.
Default:
<4>
Min: 1.0 kHz
Max: 15.0 kHz
182
C6-06
(228H)
PWM Method
Selects PWM modulation method.
0: 2-phase/3-phase conversion
1: 2-phase modulation
2: 3-phase modulation
Default: 0
Min: 0
Max: 2
182
C6-09
(22BH)
Carrier Frequency during
Rotational Auto-Tuning
0: Carrier Frequency = 5 kHz
1: Setting value for C6-03
Default: 0
Min: 0
Max: 1
182
C6-21
(245H)
Inspection Operation Carrier
Frequency
Sets the carrier frequency during Inspection Run.
0: Setting value for C6-03
1: Carrier Frequency = 2 kHz
Default: 1
Min: 0
Max: 1
182
C6-23
(25EH)
Carrier Frequency during Initial
Motor Pole Search
Sets the carrier frequency when estimating the initial polarity.
0: Carrier Frequency = 2 kHz
1: Setting value for C6-03
Default: 0
Min: 0
Max: 1
182
C6-31
(77AH)
<39>
Carrier Frequency during Rescue
Operation
Sets the carrier frequency during Rescue Operation.
0: C6-03 setting
1: 2 kHz
Default: 0
Min: 0
Max: 1
182
No.(Addr.) Name Description Setting Page
common_
TMonly
CLV
CLV/PM
V/f OLV
CLV
CLV/PM
V/f OLV
common_
TMonly
All Modes
common_
TMonly
All Modes
common_
TMonly
common_
TMonly
CLV
CLV/PM
V/f OLV
All Modes
common_
TMonly
common_
TMonly
CLV
CLV/PM
V/f OLV
All Modes
common_
TMonly
SIEP_C710616_38F_5_0.book 399 ージ 015年11月9日 月曜日 午後3時36分

Table of Contents

Other manuals for YASKAWA L1000A

Related product manuals