B.3 Parameter Table
404 YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual
■ E5: PM Motor Settings
E4-02
(322H)
Motor 2 Rated Slip
Sets the rated slip for motor 2. Automatically set during Auto-Tuning.
Default:
<4>
Min: 0.00 Hz
Min: 20.00 Hz
192
E4-03
(323H)
Motor 2 Rated No-Load Current
Sets the no-load current for motor 2. Automatically set during Auto-Tuning.
Default:
<4>
Min: 0 A
Min: [E4-01]
<10>
192
E4-04
(324H)
Motor 2 Motor Poles
Sets the number of poles of motor 2. Automatically set during Auto-Tuning.
Default: 4
Min: 2
Max: 48
192
E4-05
(325H)
Motor 2 Line-to-Line Resistance
Sets the phase-to-phase resistance for motor 2. Automatically set during Auto-Tuning.
Default:
<4>
Min: 0.000 Ω
Max: 65.000 Ω
193
E4-06
(326H)
Motor 2 Leakage Inductance
Sets the voltage drop for motor 2 due to motor leakage inductance as a percentage of rated
voltage. Automatically set during Auto-Tuning.
Default:
<4>
Min: 0.0%
Max: 40.0%
193
<4> Default setting value is dependent on the drive model (o2-04).
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU20008 to 20033, 40005 to 40018, and
50003 to 50013 display values in 0.01 A units, while models CIMR-LU20047 to 20415, 40024 to 40605, and 50017 to
50200 display values in 0.1 A units.
No.(Addr.) Name Description Setting Page
E5-02
(32AH)
<1>
<1> Parameter setting value is not reset to the default value when the drive is initialized.
<4> Default setting value is determined by the drive model (o2-04).
<10> The display resolution depends on the rated output power of the drive. Models CIMR-LU20008 to 20033, 40005 to 40018, and
50003 to 50013 display values in 0.01 A units, while models CIMR-LU20047 to 20415, 40024 to 40605, and 50017 to 50200
display values in 0.1 A units.
<43> When PG-E3 option connected: Max setting = 48
Motor Rated Power
Sets the rated capacity of the motor.
Default:
<4>
Min: 0.10 kW
Max: 650.00 kW
193
E5-03
(32BH)
<1>
Motor Rated Current
Sets the motor rated current.
Default:
<4>
Min: 10% of drive rated
current
Max: 200% of drive
rated current
<10>
193
E5-04
(32CH)
<1>
Number of Motor Poles
Sets the number of motor poles.
Default: 12
Min: 2
Max: 120
<43>
193
E5-05
(32DH)
<1>
Motor Stator Resistance
(Single Phase)
Sets the stator resistance (1 phase value).
Default:
<4>
Min: 0.000 Ω
Max: 65.000 Ω
193
E5-06
(32EH)
<1>
Motor d-Axis Inductance
Sets the d-axis inductance.
Default:
<4>
Min: 0.00 mH
Max: 600.00 mH
194
E5-07
(32FH)
<1>
Motor q-Axis Inductance
Sets the q-axis inductance.
Default:
<4>
Min: 0.00 mH
Max: 600.00 mH
194
E5-09
(331H)
<1>
Motor Induction Voltage Constant 1
Sets the induced phase peak voltage in units of 0.1 mV (rad/s) [electrical angle].
When setting this parameter, E5-24 should be set to 0.0.
Default:
<4>
Min: 0.0 mV/(rad/s)
Max:
6500.0 mV/(rad/s)
194
E5-11
(333H)
Encoder Offset
Sets the offset between the rotor magnetic axis and the encoder zero position. Set during
Encoder Offset Tuning.
Default: 0.0 deg
Min: -180 deg
Max: 180 deg
194
E5-24
(353H)
Motor Induction Voltage Constant 2
Sets the induced phase-to-phase rms voltage in units of 0.1 mV/(r/min) [mechanical angle].
When setting this parameter, E5-09 should be set to 0.0.
Default:
0.0 mV/(r/min)
Min:
0.0 mV/(r/min)
Max:
6500.0 mV/(r/min)
194
No.(Addr.) Name Description Setting Page
SIEP_C710616_38F_5_0.book 404 ページ 2015年11月9日 月曜日 午後3時36分