D.3 UL and CSA Standards
YASKAWA ELECTRIC SIEP C710616 38F YASKAWA AC Drive - L1000A Technical Manual 485
Standards Compliance
D
Note: Use crimp insulated terminals or insulated tubing for wiring these connections. Wires should have a continuous maximum
allowable temperature of 7C (167°F) 600 V UL approved vinyl sheathed insulation. Ambient temperature should not exceed
40°C (104°F).
Table D.6 Wire Gauge and Torque Specifications (Three-Phase 600 V Class)
40260
<1>
R/L1, S/L2, T/L3 500 2/0 to 600
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 500 2/0 to 600
–, +1 3/0 to 600
+3 1 to 325 M10
18 to 23
(159 to 204)
22 to 350M12
32 to 40
(283 to 354)
40304
<1>
R/L1, S/L2, T/L3 4/0 × 2P 3/0 to 600
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 4/0 × 2P 3/0 to 600
–, +1 4/0 to 600
+3 3/0 to 600 M10
18 to 23
(159 to 204)
11 to 350M12
32 to 40
(283 to 354)
40370
<1> <2>
R/L1, S/L2, T/L3 300 × 2P 4/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 300 × 2P 4/0 to 300
–, +1 3/0 to 300
+3 3/0 to 300
11 to 3/0
40450
<1> <2>
R/L1, S/L2, T/L3 3/0 × 4P 3/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 4/0 × 4P 3/0 to 300
–, +1 1/0 to 300
+3 1/0 to 300
1/0 1/0 to 300
40605
<1> <2>
R/L1, S/L2, T/L3 300 × 4P 4/0 to 300
M12
32 to 40
(283 to 354)
U/T1, V/T2, W/T3 300 × 4P 4/0 to 300
–, +1 1/0 to 300
+3 1/0 to 300
2/0 2/0 to 300
<1> Drive models CIMR-LU40045 to 40260 require the use of closed-loop crimp terminals for UL/cUL compliance. Use only the tools
recommended by the terminal manufacturer for crimping.
<2> When an EMC filter is installed, take additional measures to comply with IEC/EN 61800-5-1. Refer to EMC Filter Installation on page 477
for details.
Model
CIMR-LU
Terminal
Recomm. Gauge
AWG, kcmil
Wire Range
AWG, kcmil
Screw
Size
Tightening Torque
Nm (lb.in.)
50003
50004
R/L1, S/L2, T/L3 14 14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3 14 14 to 10
–, +1, +2 14 to 10
B1, B2 14 to 10
10 14 to 10
50006
R/L1, S/L2, T/L3 14 14 to 10
M4
1.2 to 1.5
(10.6 to 13.3)
U/T1, V/T2, W/T3 14 14 to 10
–, +1, +2 14 to 10
B1, B2 14 to 10
10 12 to 10
500010
R/L1, S/L2, T/L3 10 14 to 6
M4
2.1 to 2.3
(18.6 to 20.4)
U/T1, V/T2, W/T3 14 14 to 6
–, +1, +2 14 to 6
B1, B2 14 to 10
8 12 to 8 M5
2.0 to 2.5
(17.7 to 22.1)
Model
CIMR-LU
Terminal
Recommended Gauge
AWG, kcmil
Applicable Gauge
AWG, kcmil
Screw
Size
Tightening Torque
Nm (lb.in.)