9.1 Alarm Displays and Troubleshooting
9-7
9
A.84
A.84: Encoder Data Error
Display and Outputs
Note: OFF: Output transistor is OFF (alarm state).
Status and Remedy for Alarm
Alarm Outputs
Alarm Code Outputs ALM Output
ALO1 ALO2 ALO3
OFF OFF OFF OFF
Cause Remedy
A Encoder is defective. Replace the servomotor if the error occurs
frequently.
B Operational error in encoder caused by exter-
nal noise.
Check and correct wiring around the
encoder as follows:
Grounding of the servomotor
Separation between the encoder cable
and the servomotor power cable
Insertion of toroidal cores onto cables
At power ON
A
During operation
B