5.1 Manipulating Parameters (Pn)
5.1.4 Write Prohibition Setting for Parameters
5
Basic Functions That Require Setting before Operation
5-9
6.
To enable the new setting, turn the power supply to the SERVOPACK OFF and ON
again.
This concludes the procedure to prohibit or permit writing parameter settings.
Restrictions
If you prohibit writing parameter settings, you will no longer be able to execute some functions.
Refer to the following table.
SigmaWin+ Digital Operator
When Writ-
ing Is Pro-
hibited
Reference
Button in
Menu
Dialog Box
SigmaWin+ Function
Name
Fn No. Utility Function Name
Setup
Origin Search
Fn003 Origin Search
Cannot be
executed.
page 7-19
Absolute Encoder Reset Fn008 Reset Absolute Encoder
Cannot be
executed.
page 5-47
Adjusting the Analog Moni-
tor Output
Fn00C
Adjust Analog Monitor Output
Offset
Cannot be
executed.
page 9-10
Fn00D
Adjust Analog Monitor Output
Gain
Cannot be
executed.
page 9-10
Motor Current Detection
Offset Adjustment
Fn00E
Autotune Motor Current
Detection Signal Offset
Cannot be
executed.
page 6-30
Fn00F
Manually Adjust Motor Cur-
rent Detection Signal Offset
Cannot be
executed.
Multiturn Limit Setting
Fn013
Multiturn Limit Setting after
Multiturn Limit Disagreement
Alarm
Cannot be
executed.
page 6-19
Reset Configuration Error
of Option Module
Fn014
Reset Option Module Config-
uration Error
Cannot be
executed.
page 14-46
Vibration Detection Level
Initialization
Fn01B
Initialize Vibration Detection
Level
Cannot be
executed.
page 6-26
Setting the Origin of the
Absolute Linear Encoder
Fn020
Set Absolute Linear Encoder
Origin
Cannot be
executed.
page 5-49
Software Reset Fn030 Software Reset
Can be
executed.
page 6-24
Polarity Detection Fn080 Polarity Detection
Cannot be
executed.
page 5-27
Tuning-less Level Setting Fn200 Tuning-less Level Setting
Cannot be
executed.
page 8-11
EasyFFT Fn206 Easy FFT
Cannot be
executed.
page 8-95
Parameters Initialize Servo* Fn005 Initialize Parameters
Cannot be
executed.
page 5-10
Tuning
Autotuning without Refer-
ence Input
Fn201
Advanced Autotuning with-
out Reference
Cannot be
executed.
page 8-23
Autotuning with Reference
Input
Fn202
Advanced Autotuning with
Reference
Cannot be
executed.
page 8-34
Custom Tuning Fn203 One-Parameter Tuning
Cannot be
executed.
page 8-42
Anti-Resonance Control
Adjustment
Fn204
Adjust Anti-resonance Con-
trol
Cannot be
executed.
page 8-51
Vibration Suppression Fn205 Vibration Suppression
Cannot be
executed.
page 8-56
Continued on next page.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the YASKAWA SGDV-OCA05A and is the answer not in the manual?

YASKAWA SGDV-OCA05A Specifications

General IconGeneral
BrandYASKAWA
ModelSGDV-OCA05A
CategoryController
LanguageEnglish

Related product manuals