EasyManua.ls Logo

YASKAWA SGDV-OCA05A

YASKAWA SGDV-OCA05A
576 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.2 Alarm Displays
14.2.1 List of Alarms
14-10
A.F50
Servomotor Main Circuit
Cable Disconnection
The Servomotor did not operate or power was
not supplied to the Servomotor even though the
Servo ON command was input when the Servo-
motor was ready to receive it.
Gr.1 Yes
FL-1*
System Alarm
An internal program error occurred in the SER-
VOPACK.
No
FL-2*
FL-3*
FL-4*
FL-5*
FL-6*
CPF00
Digital Operator Commu-
nications Error 1
Communications were not possible between the
Digital Operator (model: JUSP-OP05A-1-E) and
the SERVOPACK (e.g., a CPU error occurred).
No
CPF01
Digital Operator Commu-
nications Error 2
* These alarms are not stored in the alarm history. They are only displayed on the panel display.
Continued from previous page.
Alarm
Number
Alarm Name Alarm Meaning
Servo-
motor
Stop-
ping
Method
Alarm
Reset
Possi-
ble?

Table of Contents