14.2 Alarm Displays
14.2.1 List of Alarms
14-10
A.F50
Servomotor Main Circuit
Cable Disconnection
The Servomotor did not operate or power was
not supplied to the Servomotor even though the
Servo ON command was input when the Servo-
motor was ready to receive it.
Gr.1 Yes
FL-1*
System Alarm
An internal program error occurred in the SER-
VOPACK.
No
FL-2*
FL-3*
FL-4*
FL-5*
FL-6*
CPF00
Digital Operator Commu-
nications Error 1
Communications were not possible between the
Digital Operator (model: JUSP-OP05A-1-E) and
the SERVOPACK (e.g., a CPU error occurred).
No
CPF01
Digital Operator Commu-
nications Error 2
* These alarms are not stored in the alarm history. They are only displayed on the panel display.
Continued from previous page.
Alarm
Number
Alarm Name Alarm Meaning
Servo-
motor
Stop-
ping
Method
Alarm
Reset
Possi-
ble?