14.2 Alarm Displays
14.2.2 Troubleshooting Alarms
14-14
A.070:
Motor Type
Change Detected
(The connected
motor is a differ-
ent type of motor
from the previ-
ously connected
motor.)
A Rotary Servomotor
was removed and a
Linear Servomotor
was connected.
Set the parameters for a
Linear Servomotor and
reset the motor type
alarm. Then, turn the
power supply to the SER-
VOPACK OFF and ON
again.
page 14-48
A Linear Servomotor
was removed and a
Rotary Servomotor
was connected.
Set the parameters for a
Rotary Servomotor and
reset the motor type
alarm. Then, turn the
power supply to the SER-
VOPACK OFF and ON
again.
page 14-48
A.080:
Linear Encoder
Pitch Setting
Error
The setting of Pn282
(Linear Encoder Pitch)
has not been changed
from the default set-
ting.
Check the setting of
Pn282.
Correct the setting of
Pn282.
page 5-17
A.0b0:
Invalid Servo ON
Command Alarm
A Servo ON com-
mand (Enable = 1)
was input from the
host controller after a
utility function that
turns ON the Servo-
motor was executed.
Turn the power supply to
the SERVOPACK OFF and
ON again. Or, execute a
software reset.
page 6-24
Continued on next page.
Continued from previous page.
Alarm Number:
Alarm Name
Possible Cause Confirmation Correction Reference

Table of Contents