7. Technical Parameters
Power supply
Mains supply: 240 / 12 V; 1 A, power adapter
Direct current supply:9 to 30 V DC
Consumption 12 V DC:
at rest – 100 mA
Internal batteries: 4x NiMH type AA, 1.2 V / min. 2000 mAh
Configuration and upgrade
Local:WEB UI via USB
Cloud service: 2N
®
Elevator Center
Antenna
Connector type:SMA
Impedance: 50 Ω
Line interface
Interface type: 2-wire analog, FXS
Call impedance: selectable– 600 Ω, Zr EU, Zr Australia
Loop voltage: 48 V DC
Loop current: 20 mA
Loop resistance: 800 Ω max
Ringing voltage: adjustable, 35–60 V RMS
Ringing frequency: adjustable, 10–60 Hz
INPUT
Shorting input
OUTPUT
Type: Relay output
Contacts: Switching, with normally open and normally closed
Switched voltage DC:30 V, 1 A max
Switched voltage AC:125 V, 0.3 A max
Resistive load
Serial Line
Type: RS232
Warning
2N only guarantees the quality of the2N
®
EasyGate IPwhen using power adapters
supplied by 2N. If other power adapters are used, 2N cannot guarantee error-free
operation of the device.

Table of Contents

Other manuals for 2N EasyGate IP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the 2N EasyGate IP and is the answer not in the manual?

2N EasyGate IP Specifications

General IconGeneral
Brand2N
ModelEasyGate IP
CategoryGateway
LanguageEnglish

Related product manuals