2N® EasyGate IP User Manual
•
•
•
•
•
•
•
•
•
•
•
Service – enable / disable RS232 data connection using TCP.
State – display the current TCP state.
Idle Time – set the timeout after which the TCP server connection is terminated if no data
is transmitted.
FIFO Queue Size – set the queue size according to the FIFO rules (first in, first out).
Transmission Debugging – enable data transmission to the log in both directions to
monitor the whole RS232 - server communication.
5.9.2.1 TCP
State– display the current TCP state.
Server Name– set the TCP server name.
Server Port– set the TCP server port.
TCP no delay– allow instantaneous sending of data received by the device. By allowing
the function you force instantaneous sending of data to the TCP server.
Connection Timeout– define how long2N
®
EasyGate IPshall try to establish connection
with the TCP server.
Reconnect– enable the parameter to make2N
®
EasyGate IPtry to reconnect in the case
of a socket error. The device shall repeat the attempts until the end of the connection
timeout.