RX Gain – set the receiving line gain. The default value is −2 dB.
TX Gain – set the transmission line gain. The default value is −2 dB.
Line Impedance – set the FXS line impedance.
Line current limit – set a line current value ranging from 15–40 mA.
Tone Volume – set the DTMF tone volume.
Enable AGC – enable/disable Automatic Gain Control for the line signal.
DTMF mute time – set the tone dialing mute time. Mute time is only supported for the RFC
and SIP info types of DTMF.
Calling Party Control – use the call end signaling by CPC (Calling Party Control), during
which the line current is interrupted for a while.