RESET A short press restarts the device. A long press (20 s) resets the device
factory values.
USB
Used for local access to the web interface settings via the 2N
®
EasyGate
IP – 2N Web Configuration Utility.
SIM1 Primary SIM card slot.
ANTENNA
CONNECTOR
SMA antenna connector. For US version support there are two antenna
connectors.
SIM2 Secondary SIM card slot for primary SIM backup at signal loss.
POWER Power supply connector.
EXT BATTERY Connector for remote connection of 4 external NiMH batteries outside
the device.Power is withdrawn from the external battery automatically
in the case of an electrical power failure. Make sure that the internal
batteries are removed before connecting external batteries!
O/I Device on/off switch.
2.5 Overview of LED Indicators
The status of2N EasyGate IPis signaled by the LED indicators on the device upper side. Refer to
the table below for the statuses.
LED Indicators
Power supply
Blue – mains power
Blue flashing for 1.8 s, followed by 0.2s pause – problem with 2N Lift1
setup
Red – HW error
When an HW error is indicated by a red LED, request rectification or
compensation from your distributor.
Green – battery power
Yellow – battery removal required, two-year life exceeded