EasyManua.ls Logo

ABB ACS6000 - CDP Control Panel; EMERGENCY off Latching; Emergency-Off Reset; INU Control Panels

ABB ACS6000
278 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3BHS212794 E01 REV M ACS6000 USER MANUAL 175/278
08 OPERATION
8.4.2 INU control panels
The control panel for motor 1 (A in Fig. 8-2) is on the door of control
unit COU1.
The location of additional control panels (B in Fig. 8-2) depends on the
configuration of the drive (eg, single-motor or multi-motor drive, drive for
motors with double windings).
Figure 8-2 INU control panel for motor 1 (A) and additional motors (B)
(1) CDP control panel
Main functions:
Starts and stops the motor
Displays status messages of the INU
Displays alarm and fault messages of
the drive and monitored foreign
equipment
Resets alarm and fault messages
(2) Main power supply off
Illuminated pushbutton opens the
main circuit breaker
(3) Main power supply on Illuminated
pushbutton charges the DC link
and closes the main circuit breaker
(4) Alarm / fault lamp
Alarm: flashing light
Fault: permanent light
(5) EMERGENCY-OFF RESET
pushbutton
Resets the emergency-off relay in the
drive control system
Flashes when the auxiliary voltage is
switched on, or when an emergency-
off pushbutton is pressed
(6) EMERGENCY OFF latching
pushbutton
Prevents starting when pressed at
standstill of the drive
Main circuit breaker opens and DC
link discharges when pressed during
operation of the drive
AB
1 1
2 23
4 45
6 6

Table of Contents