03 POWER ELECTRONICS AND CABINET FEATURES
3BHS212794 E01 REV M ACS6000 USER MANUAL 78/278
3.3.5.1 DCS800 control panel
The control panel of the DCS800 unit enables the user to control, read the
status messages and set the parameters of the DCS800 unit. The panel
can also be used to copy parameters from one DCS800 unit to
another DCS800.
Note: For more information, see 8.5 EXU control panel on page 178.
3.3.5.2 Reversing switch
The EXU for brushless excitation is equipped with a reversing switch for
changing the sense of rotation. The switch is actuated by the drive.
The switch changes the sense of rotation via the optical communication
link. When the drive is in state ReadyOn or NotReadyOn, the switch
is opened.
3.3.5.3 Output disconnector
The optional output disconnector is used to disconnect the EXU from the
motor for maintenance purposes.