10 PREVENTIVE AND CORRECTIVE MAINTENANCE
3BHS212794 E01 REV M ACS6000 USER MANUAL 238/278
3. Slide the locking bar from the unlocked (1) to the locked (2) position.
Door hinged on the left:
Door hinged on the right:
IMPORTANT! A limit switch monitors the locked position. If a door is
not locked properly, you cannot start the drive.
10.4.6 Testing the white lamp
If the lamp does not turn on, proceed as follows:
1. To test the lamp, press its lamp cap (1 in Fig. 10-10).
Lamp does not turn on:
- Lamp is burnt out
- Lamp-test circuit is faulty
The lamp-test circuit and the door releasing circuit are
independent of each other. From the lamp not lighting up, it
cannot be concluded that the door releasing circuit is
not working.
Lamp turns on:
- Door releasing circuit is malfunctioning.