Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / uint16ACS800-compatible fault word 2.
The bit assignments of this word correspond to FAULT
WORD 2 in the ACS800. Parameter 4.120 Fault/Warning
word compatibility determines whether the bit assignments
are according to the ACS800 Standard or ACS800 System
control program.
Each bit can indicate several ACS880 events as listed
below.
This parameter is read-only.
ACS880
events indic-
ated by this bit
(see Fault tra-
cing (page 537))
ACS880 fault name
Bit
(4.120 =
ACS800 Sys-
tem ctrl pro-
gram)
(4.120 =
ACS800 Stand-
ard ctrl pro-
gram)
3130
SUPPLY
PHASE
SUPPLY
PHASE
0
-NO MOTOR
DATA
NO MOT DATA1
3220
DC UNDER-
VOLT
DC UNDER-
VOLT
2
4000
CABLE TEMPReserved3
AFEB
RUN DISABLERUN ENABLE4
7301, 7380,
7381, 73A0,
73A1
ENCODER
ERR
ENCODER
ERR
5
7080, 7082
IO COMM ERRI/O COMM6
-CTRL B TEMPCTRL B TEMP7
9082
SELECTABLEEXTERNAL
FLT
8
-OVER SW-
FREQ
OVER SW-
FREQ
9
80A0
AI<MIN FUNCAI < MIN
FUNC
10
5681, 5682,
5690, 5691,
5692, 5693,
5694, 5695
PPCC LINKPPCC LINK11
6681, 7510,
7520, 7581
COMM MOD-
ULE
COMM MOD-
ULE
12
7081
PANEL LOSSPANEL LOSS13
7121
MOTOR
STALL
MOTOR
STALL
14
3381
MOTOR
PHASE
MOTOR
PHASE
15
Fault word 24.22
- / uint16
(Only visible with a BCU control unit)
Indicates which parallel-connected modules have faulted.
The bits of this word are cleared when all faults have been
reset.
This parameter is read-only.
Faulted modules4.25
1 = Module 1 faultedModule 1b0
1 = Module 2 faultedModule 2b1
1 = Module 3 faulted.Module 3b2
Parameters 147