Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
Not selected / uint32
When parameter 50.8 FBA A actual 2 type is set to
Transparent or General, this parameter selects the source
of actual value 2 transmitted to the fieldbus network through
fieldbus adapter A.
FBA A act2
transparent source
50.11
0No source selected.Not selected
See Terms and abbreviations (page 132).
Other
Disable / uint16Enables the display of raw (unmodified) data received from
and sent to fieldbus adapter A in parameters 50.13…50.18.
This functionality should only be used for debugging.
Note: This parameter cannot be changed while the drive
is running.
FBA A debug mode50.12
0Display of raw data from fieldbus adapter A disabled.Disable
1Display of raw data from fieldbus adapter A enabled.Fast
0 / uint32Displays the raw (unmodified) control word sent by the
master (PLC) to fieldbus adapter A if debugging is enabled
by parameter 50.12 FBA A debug mode.
This parameter is read-only.
FBA A control word50.13
1 = 1Control word sent by master to fieldbus adapter A.00000000…FFFFFFFFh
- / int32Displays raw (unmodified) reference REF1 sent by the
master (PLC) to fieldbus adapter A if debugging is enabled
by parameter 50.12 FBA A debug mode.
This parameter is read-only.
FBA A reference 150.14
- / int32Displays raw (unmodified) reference REF2 sent by the
master (PLC) to fieldbus adapter A if debugging is enabled
by parameter 50.12 FBA A debug mode.
This parameter is read-only.
FBA A reference 250.15
0 / uint32Displays the raw (unmodified) status word sent by fieldbus
adapter A to the master (PLC) if debugging is enabled by
parameter 50.12 FBA A debug mode.
This parameter is read-only.
FBA A status word50.16
1 = 1Status word sent by fieldbus adapter A to master.00000000…FFFFFFFFh
- / int32Displays raw (unmodified) actual value ACT1 sent by
fieldbus adapter A to the master (PLC) if debugging is
enabled by parameter 50.12 FBA A debug mode.
This parameter is read-only.
FBA A actual value 150.17
- / int32Displays raw (unmodified) actual value ACT2 sent by
fieldbus adapter A to the master (PLC) if debugging is
enabled by parameter 50.12 FBA A debug mode.
This parameter is read-only.
FBA A actual value 250.18
418 Parameters