Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / uint16Displays (in integer format) the data received from the
external controller as word 3 of data set 24.
A target for this data can be selected by parameter 62.74
Data set 24 data 3 selection. The value can also be used
as a source by another parameter.
Data set 24 data 3
value
62.124
- / -Data received as word 3 of data set 24.0...65535
LSU SW / uint32
(Parameters 62.15162.203 only visible when supply unit
control activated by 95.20)
Parameters 62.15162.153 define a target for the data
received in data set 11 from another converter (typically
the supply unit of the drive).
Parameters 62.20162.203 display the data received from
the other converter in integer format, and can be used as
sources by other parameters.
For example, this parameter selects a target for word 1 of
data set 11. Parameter 62.201 INU-LSU data set 11 data
1 value displays the received data in integer format, and
can also be used as a source by other parameters.
INU-LSU data set 11
data 1 sel
62.151
0None.None
4Status word of the supply unit.LSU SW
See Terms and abbreviations (page 132).
Other
None / uint32Defines a target for the data received as word 2 of data
set 11.
See also parameter 62.202 INU-LSU data set 11 data 2
value.
For the selections, see parameter 62.151 INU-LSU data
set 11 data 1 sel.
INU-LSU data set 11
data 2 sel
62.152
None / uint32Defines a target for the data received as word 3 of data
set 11.
See also parameter 62.203 INU-LSU data set 11 data 3
value.
For the selections, see parameter 62.151 INU-LSU data
set 11 data 1 sel.
INU-LSU data set 11
data 3 sel
62.153
- / uint16Displays (in integer format) the data received from the other
converter as word 1 of data set 11.
A target for this data can be selected by parameter 62.151
INU-LSU data set 11 data 1 sel. The value can also be
used as a source by another parameter.
INU-LSU data set 11
data 1 value
62.201
- / -Data received as word 1 of data set 11.0...65535
- / uint16Displays (in integer format) the data received from the other
converter as word 2 of data set 11.
A target for this data can be selected by parameter 62.152
INU-LSU data set 11 data 2 sel. The value can also be
used as a source by another parameter.
INU-LSU data set 11
data 2 value
62.202
- / -Data received as word 2 of data set 11.0...65535
- / uint16Displays (in integer format) the data received from the other
converter as word 3 of data set 11.
A target for this data can be selected by parameter 62.153
INU-LSU data set 11 data 3 sel. The value can also be
used as a source by another parameter.
INU-LSU data set 11
data 3 value
62.203
470 Parameters