What to doCause
Event name /
Aux. code
Code
(hex)
Check the sticker on the memory unit to
confirm that the firmware is compatible
with the control unit (ZCU-1x/BCU-x2).
Connect Drive Composer PC tool
(version 2.3 or later) to the drive. Select
Tools - Recover drive.
If the problem persists, replace the
memory unit.
Check the nominal motor values in
parameter group 99 Motor data.
Motor ID run was not completed
successfully.
ID runFF61
Check that no external control system is
connected to the drive.
Cycle the power to the drive (and its
control unit, if powered separately).
Check that the motor shaft is not locked.
Check the auxiliary code. The second
number of the code indicates the problem
(see actions for each code below).
Check settings of parameters 99.6
Motor nominal current and 30.17
Maximum current limit too low.0001
Maximum current. Make sure that
30.17 Maximum current > 99.6 Motor
nominal current.
Check that the drive is dimensioned
correctly according to the motor.
Check that SLS function is not active.Maximum speed limit or calculated
field weakening point too low.
0002
Check settings of parameters
•
30.11 Minimum speed
•
30.12 Maximum speed
•
99.7 Motor nominal voltage
•
99.8 Motor nominal frequency
•
99.9 Motor nominal speed.
Make sure that
•
30.12 Maximum speed > (0.55 ×
99.9 Motor nominal speed) >
(0.50 × synchronous speed)
•
30.11 Minimum speed < 0, and
•
supply voltage > (0.66 × 99.7
Motor nominal voltage).
Check settings of parameter 99.12
Motor nominal torque, and the torque
limits in group 30 Limits.
Maximum torque limit too low.0003
Make sure that the maximum torque
limit in force is greater than 100%.
Contact your local ABB representative.Current measurement calibration did
not finish within reasonable time.
0004
Contact your local ABB representative.Internal error.0005…0008