Timer Description Default
Audible
Internal Bells
INT BELL TIME
Duration that internal sounders will sound when alarm is
activated. (0–999 minutes; 0=never)
15 min.
External Bells
EXT BELL TIME
Duration that external sounders will sound when alarm is
activated. (0–999 minutes; 0=never)
15 min.
External Bell Delay
EXT BELL DELAY
This will cause a delayed activation of the external bell. (0–
999 seconds)
0 sec.
External Bell Delay Partset Delay period before external bells are activated in partset
mode.
0 sec
Chime
CHIME TIME
Number of seconds that a chime output will activate, when a
zone with chime attribute opens. (1–10 seconds)
2 sec.
Confirmation
Confirm
CONFIRM TIME
Note: This option is only available for certain Grade and
Confirmation option combinations. (See Options on
page169 and Standards on page184.)
This timer applies to the alarm confirmation feature and is
defined as the maximum time between alarms from two
different non overlapping zones that will cause a confirmed
alarm. (0–60 minutes)
30 min.
Confirmed holdup Note: This option is only available for certain Grade and
Confirmation option combinations. (See Options on
page169 and Standards on page184.)
This timer applies to the confirmed holdup feature and is
defined as the maximum time between alarms from two
different non-overlapping zones that will cause a confirmed
alarm. (480–1200 minutes)
480 min.
Dialer Delay
DIALER DELAY
When programmed, the dialler delay initiates a predefined
delay period before the system dials out to an Alarm
Receiving Centre (ARC). This is specifically designed to
reduce unwarranted responses from Alarm Receiving
Centres and the constabulary. In the event of a subsequent
zone being tripped the dialler delay period is ignored and the
dialler dials out immediately. (0–999 seconds)
30 sec.
Partset Dialer Delay Delay period after a Partset alarm has been activated before
system makes a call to ARC.
30 sec
Alarm abort
ALARM ABORT
Time after a reported alarm in which an alarm abort
message can be reported. (0–999 seconds)
30 sec.
SPC42/52/53/63 Installation & Configuration Manual Engineer programming via the browser
© Vanderbilt 2023 180 I-200572
08.12.2023

Table of Contents