Zone Type
Processing
Category
Description
DETECTOR FAULT Fault Detector Fault zones are 24 hour zones that are applicable to a
detector device, for example, a PIR. The fault zone type triggers the
Fault output.
When the system is armed, a fault output is triggered. Both the keypad
LED and the buzzer are activated when Unarmed.
LOCK
SUPERVISION
Intruder Only available in Commercial mode.
Used to monitor a door lock. System can be programmed not to set
unless door is locked.
SEISMIC Intruder Only available if the panel is in Financial mode of operation. Vibration
sensors, also called seismic sensors, are used to detect intrusion
attempts by mechanical means, such as drilling or making holes
through walls or safes.
ALL OKAY Intruder This zone type enables a special entry procedure to be implemented
using a user code and ‘All Okay’ input. A silent alarm is generated if an
All Okay button is not pressed within a configurable time after a user
code is entered. (See Adding/Editing an area on page186 for details of
‘All Okay’ configuration.)
All Okay uses two outputs, Entry Status (Green LED) and Warning
Status (Red LED), to indicate entry status using LEDs on the keypad.
UNUSED Intruder Allows a zone to be disabled without the need for each zone to have
EOL resistors fitted. Any activation on the zone will be ignored.
HOLDUP FAULT Fault Holdup Fault zones are 24 hour zones that are applicable to a holdup
signaling device, for example, a WPA. The fault zone type triggers the
Fault output.
When the system is armed, a fault output is triggered. Both the keypad
LED and the buzzer are activated when Unarmed.
This zone type will report the SIA messages, HT (Holdup Trouble) and
HJ (Holdup Trouble Restore) and for CID, a sensor trouble event (380)
is produced.
WARNING FAULT Fault Warning Fault zones are 24 hour zones that are applicable to a
warning signaling device, for example, an internal or external bell. The
fault zone type triggers the Fault output.
When the system is armed, a fault output is triggered. Both the keypad
LED and the buzzer are activated when Unarmed.
This zone type will report the SIA messages, YA (Bell Fault) and YH
(Bell Restore) and for CID, a sensor trouble event (380) is produced.
Note: On a grade 2 system, a cable fault will cause a fault and not an
alarm.
SETTING
AUTHORISATION.
Intruder Applicable to Blockschloss operation. This zone type is used to send a
setting authorisation signal to the panel that the Blockschloss is ready
to set. The Set option must be selected for the ‘Setting Authorisation‘
attribute for the area