Programming Control
32.
Low Power/Auto Shutdown D
Days Enable
"LPSd"
This option allows the owner to set
Low
Power/Auto
Shutdown on certain day(s)
of
the week.
Low
Power
or
Auto Shutdown duration are programmed using an
external device or network.
How
to
Program the
Low
Power/Auto
Shutdown D Days Enable
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2.
Press the DELICATESIBULKY
(1\)
or
the
COLD
(v)
keypad until
"Prog"
appears in the
display. Press the START (enter) keypad and
"AtS1" will appear in the display.
3. Press the DELICATESIBULKY
(1\)
or
the
COLD
(v)
keypad to scroll through the
programmable options until
"LPSd" appears in
the display.
4.
When "LPSd" appears in the display, press the
START (enter) keypad. The current
Low
Power/
Auto Shutdown D Days Enable status will appear
in the display.
"on" Option Enabled
"oFF"
=Option Disabled
(factory default setting)
5. Press the
DELICATESIBULKY
(1\)
or
the
COLD
(v)
keypad to change the current status.
6. Press the START (enter) keypad when the correct
status appears in the display.
The
next option,
"PFr",
will appear in the display.
NOTE:
To
program
"PFr"
(power Fall Reset),
refer to
option 33.
To
program
other options, refer
to the appropriate section.
How
to
Exit Programming Feature
Press the WARM
«)
keypad until the control returns
to Ready Mode.
33.
Power Fail Reset
"PFr"
This option allows the owner to set the amount
of
time
the control will store active cycle information in the
event
of
a power failure. The default setting for Power
Fail Reset is OFF.
If
Power Fail Reset is turned OFF,
the cycle will
be
saved.
How
to
Program Power Fail Reset
1.
Control must
be
in Manual Mode. Refer to
Entering the Manual Mode.
2.
Press the DELICATESIBULKY
(1\)
or
the
COLD
(v)
keypad until
"Prog"
appears
in
the
display. Press the START ( enter) keypad and
"AtS1" will appear in the display.
3. Press the DELICATESIBULKY
(1\)
or
the
COLD
(v)
keypad to scroll through the
programmable options until "PFr" appears in the
display.
4. When
"PFr"
appears in the display, press the
START (enter) keypad.
"oFF"
or
a number will
appear in the display. This number corresponds to
the current Power Fail Reset setting.
5. Press theDELICATESIBULKY
(1\)
or the
COLD
(v)
keypad to increase or decrease the
current number to the desired number selected
from
Table
13.
6. Press the START (enter) keypad when the correct
number appears in the display. The next option,
"IrA", will appear in the display.
NOTE:
To
program
"IrA"
(lR
Access
[On/Off),
refer to option 34.
To
program
other options, refer
to the
appropriate
section.
How
to
Exit Programming Feature
Press the WARM
«)
keypad until the control returns
to Ready Mode.
80
© Published
by
permiSSion
of
the
copyright owner - DO NOT
COpy
or TRANSMIT
802952