Diagnostic Test Descriptions
Control Software Version Number Test
This option displays the control software version
number.
To
start test, control must be in the Testing
Mode. Refer to How to Enter Testing Feature at the
beginning
of
this section.
To enter, press the START (enter) keypad.
The
display
will show
"8
XX"
where "XX" is the software version
number.
To
exit the Software Version Number Test, press the
WARM
«)
keypad.
The
control will return to the
testing mode.
Service Door Opening Test
This option tests the service door switch.
To
start test,
control must be
in
the Testing Mode. Refer to How to
Enter Testing Feature
at
the beginning
of
this section.
To enter, press the START (enter) keypad.
The
display
will show
"8
oP"
when the service door switch is
open and
"8
CL" when the service door switch is
closed.
The
service door switch has to
be
closed for at least
one second and opened for
at
least a
half
a second for
the display to change. This test will add a count to the
service door opening counter for the audit and save the
date/time for each opening.
To
exit the Service Door Opening Test, press the
WARM
«) keypad.
The
control will return to the
testing mode.
Coin Vault Opening Test
This option tests the coin vault switch. To start test, the
control must
be
in the Testing Mode. Refer to How to
Enter Testing Feature at the beginning
of
this section.
To enter, press the START (enter) keypad. The display
will
show
"U
oP"
when the coin vault switch is open
and
"U
CL" when the coin vault switch is closed.
The coin vault switch has to
be
closed for at least one
second and opened for
at
least a
half
a second for the
display
to change. This test will add a count to the coin
vault opening counter for the audit and save the time/
date for each opening.
To exit the Coin Vault Opening Test, press the WARM
«)
keypad.
The
control will return to the testing
mode.
Testing Machine and Electronic Control Functions
Coin Drop
#1
Input Test
This option tests coin drop #
1.
To
start test, control
must
be
in the Testing Mode. Refer to How to Enter
Testing Feature at the beginning
of
this section.
To enter, press the START (enter) keypad. The display
will show
··C1XX".
The
"XX" will show the number
of
coins entered and will increment one for each coin
entered in coin drop
#
1.
NOTE: Coins entered in test mode will not
increment the total #
of
coins counter that
is
accessed in the audit feature.
To
exit the Coin Drop
#1
Input Test, press the WARM
«)
keypad. The control will return to the testing
mode.
Coin Drop #2 Input Test
This option tests coin drop #2. To start test, control
must
be
in the Testing Mode. Refer to How to Enter
Testing Feature
at
the beginning
of
this section.
To enter, press the START (enter) keypad.
The
display
will show
··C2XX".
The
"XX" will show the number
of
coins entered and will increment one for each coin
entered in coin drop #2.
NOTE: Coins entered in test mode will not
increment the total #
of
coins counter that is
accessed in the audit feature.
To
exit the Coin Drop #2 Input Test, press the WARM
«)
keypad.
The
control will return to the testing
mode.
Coin Drops Header Present Test (software
version
"s 02"
or
higher only)
This option tests the coin drop header connection. To
start test, control must
be
in Testing Mode. Refer to
How to Enter Testing Feature at the beginning
of
this
section.
To enter, press the START (enter) keypad.
The
display
will show
"CHoP"
when the wiring connection is
open and
"CHCL" when the connection is closed.
To exit Coin Drops Header Present Test, press the
WARM
«)
keypad.
The
control will return to the
testing mode.