Error Codes
Following is a list
of
possible error codes for an
electronic control. Errors beginning with "EI" refer to
external device Infra-red communication errors. Errors
beginning with
"EC"
refer to card reader errors. All
other errors refer to machine errors.
Display
Description
Causel
Corrective Action
EI01
Transmission Failure
Communication failure. Re-aim external device and try
again.
EI02
Time-out Error
Communication failure. Re-aim external device and try
again.
EI03
Invalid Command Code
Communication successful, but the command was not
valid for this machine type,
or
the control could not
perfonn the command in its current mode
of
operation.
Ensure data is for current machine type and control is in
correct mode.
EI04
Expecting Upload Request
Communication failure. Re-aim external device and try
again.
EI05
Invalid
or
Out-of-Range Data
The
value in at least one
of
the programming options
is
invalid
or
out
of
range. Recheck the programming
option's value and try again.
EI09
CRC-16 Error
Communication failure. Re-aim external device and
again.
EIOA
Fmming Error
Communication error. Re-aim external device and try
again.
EIOC
Time-out Exceeded
Communication error. Re-aim external device and try
again.
EIOE
Encryption Error
Communication error. Re-aim external device and try
again.
If
the problem persists, check that the security
code is correct.
EIOF
Infra-red Disabled
Communication failure
or
infra-red is disabled.
Manually enable infra-red on control
or
re-aim external
device and try again.
EC02
Time-out Error
Communication failure. Try card again.
EC03
Invalid Command Code
Communication successful, but the command
was
not
valid for this machine type,
or
the control could not
perfonn the command in its current mode
of
operation.
Ensure data is for current machine type and control is in
correct mode.
EC05
Invalid
or
Out-of-Range Data
The
value in at least one
of
the programming options is
invalid or out
of
range. Recheck the programming
option's value and try again.