Power Fail Recovery
The Power Fail Recovery feature allows the cycle
status
to
be
saved in memory in the event
of
a power
failure.
If
the power failure lasted less than 30 seconds and
the door
is locked, the cycle will resume
witho~t
requiring the user to press the
START
(enter) keypad
to restart.
If
the power failure lasted longer than 30 seconds the
Power Fail Reset option is turned "ON," the door is
unlocked, and the duration
of
the power failure is less
than or equal
to
the time programmed in the Power
Fai~
~e~et
option, the
START
(enter) keypad will flash
untd
1t
1S
pressed and the cycle will restart from the
point it left off.
If
the power failure lasted longer than 30 seconds, the
Power Fail Reset option
is
turned
"OFF,"
and the door
is unlocked,
START
(enter) keypad will flash
one
second on and one second
off
until it is pressed.
The
cycle will restart from the point it left
off
when
START
(enter) is pressed.
If
the power failure lasted longer than 30 seconds,
lasted longer than the time programmed in the Power
Fail Reset option, and the Power Fail Reset option is
turned
"ON,"
the control will flash the
START
(enter)
keypad one
(I)
second on and one
(I)
second off.
When the pad is pressed, the cycle will start a delicate
final high spin.
802952
@ Published by permission
of
the copyright owner - DO NOT
COpy
or
TRANSMIT
99